CVSS 4.0
Вероятност да бъде експлоатирана в следващите 30 дни (EPSS)
Атакува се
Време до експлоатация
Атакува се локално, без особени условия, с обикновен потребителски вход и без действие от потребителя.
- Експлоатация: няма данни за експлоатация
- Атаката не може да се автоматизира
Описание
Оригинално описание
An unprivileged, memory-protected ThreadX module can have the kernel read and write memory at addresses of its choosing, in privileged mode, and can use that to clear the MPU enable bit and remove its own isolation boundary. The Module Manager decided whether a privileged service could dereference an object address a module named by asking only whether that address fell outside the module. The manager's object pool is outside every module, so the test was satisfied by an address shifted into the interior of one of the module's own privileged allocations, which denotes no object at all. The bytes such an address presents as a control block are bytes the module put there through ordinary create and set services, so the control block ID at the front of them could be made to read as any type the module chose, and the `_txe_` layer's ID test then agreed. The reported chain uses that to reach a privileged `memset` across an attacker-chosen range.
Засегнати продукти
- Eclipse Foundation ThreadX: 6.0.1 до 6.5.1.202602a; 6.5.2.202603
Вид слабост
История
- 29 септември 2026 Публикувано